4-DIGIT RTD METER, TRANSMITTER & CONTROLLER Q9000M (0.1°)
OPTIONS Analog output for user-selected span Single-setpoint 10 A relay control Dual-setpoint 10 A relay control Proportional 4-20 mA control Time-proportional 2 A solid-state relay control Isolated parallel BCD output NEMA-4 splash-proof lens cover The QUANTA Q9000M is a 4-digit indicator/controller with a wide choice of output options. It provides 0.1 degree resolution for 100 ohm platinum RTD's with alpha of 0.00385. It is complete with sensor excitation and break detection. Readout can be in °C or °F, as selected by plug-in jumpers. POWER OPTIONS Six types of meter power are available: 120 Vac, 240 Vac, 24 Vac, 5 Vdc, isolated 9-32 Vdc, or isolated 26-56 Vdc. ANALOG OUTPUT OPTIONS A 1 mV/degree (±1 V full-scale) analog output is standard and is suitable for driving a strip-chart recorder. An additional analog output can be provided by an optional vertical plug-in board. Available output signals are 0-5 Vdc, 0-10 Vdc, 0-1 mA (source or sink), and 4-20 mA (source or sink). The top and bottom of each output range can be scaled to fit a user-selected display span. One advantage in using the Q9000M as a 4-20 mA transmitter is that the current signal tracks the display, and hence is linearized. CONTROL OUTPUT OPTIONS Additional outputs can be provided by a horizontal upper board. Available options include single-setpoint control with one 10 A relay, dual-setpoint control with two 10 A relays, 4-20 mA proportional control (source or sink), time- proportional 2 A solid-state relay control, and isolated, parallel BCD output. For additional information, please refer to the QUANTA, Options, and Mechanical sections. SPECIFICATIONS ANALOG INPUT RTD type: 100-ohm platinum with alpha of 0.00385 Calibration: To DIN 43760, October 1980 Excitation current: 0.42 mA Sensor connection: 2, 3 or 4 wires Max lead resistance: 20 ohm for 2, 3 or 4-wire connection Zero adjustment: ±5°C (±9°F) Overvoltage protection: 15 Vp NOISE REJECTION NMR: 115 dB, 50/60 Hz CMR: 120 dB CMV: 1500 Vp per HV test, 354 Vp per IEC spacing ACCURACY AT 25°C Zero tempco (bridge-network error): ±0.05 deg/deg Span tempco, 10°C to 40°C: ±0.006% of reading/°C Lead resistance effect 2-wire connection: +2.6°C (4.7°F)/ ohm 3- or 4-wire connection: compensated to 20 ohm max ANALOG-TO-DIGITAL CONVERSION Input configuration: Differential, bipolar Technique: Dual-slope, average-value Polarity: Automatic Signal integration period: 100 ms Read rate: 2.5/s DISPLAY Type: 7-segment, red LED Height: 0.56 in (14.2 mm) Symbols: 8.8.8.8 Decimal-point positions: Three positions selectable by jumpers behind lens or at connector 0 to 9,999 counts: Normal operation 10,000 to 19,999 counts: Four least-significant digits flash correct reading Beyond 19,999 counts: All four digits flash zeros Sensor-break indication: All four digits flash zeros POWER AC voltages: 120, 240 or 24 V ac +10%/15% AC frequency: 49-440 Hz DC voltages: 9-32 Vdc, isolated to 300 Vp; 26-56 Vdc, isolated to 300 Vp; 5 Vdc ±5%, non-isolated Power consumption: 5 W max ENVIRONMENTAL Operating temperature: 0 to 60°C Storage temperature: 40 to +85°C Relative humidity: 95% at 40°C (non-condensing) MECHANICAL Dimensions: Newport DIN1A (1/8 DIN) case (see Mechanical section for drawings) Weight: 17 oz (480 g) Case material: 94V-0 UL-rated polycarbonate HOME / PRODUCT GUIDE / TECHNICAL REFERENCE NEWPORT Electronics, Inc. (714) 540-4914 or Contact Us Copyright 1998, Newport Electronics, Inc. All rights reserved. |